Custom acoustic wall panels and suspended ceiling clouds installed at WellCome OM Integral Healing & Education Center in Spring Hill — cutting broadband reverb from 3+ seconds to ~1.5 across a multipurpose hall hosting yoga, seminars, weddings, and live speakers.
Case Studies
Pre-construction STC lab testing across 8 light-gauge-steel wall assemblies for a ULI-awarded Chicago multi-family developer — proving Wall Blokker Pro delivered a +5 STC delta across every gauge tested before the panelized modular building scaled up.
About 100 custom acoustic absorption panels installed via self-leveling laser layout inside a South Florida 200–300 capacity live-music hall — cutting reverberation from 2.0 seconds down to ~0.8 across a 2-day install window, a 60% reverb reduction overnight.
Pre-opening noise ordinance compliance testing for an indoor-outdoor Bywater music venue in New Orleans — Type 2 sound-level meter readings, L10 and Lmax baseline data, and a 10-minute capture plan prepped for City Council review under Chapter 66.
Wall-to-wall acoustic panel coverage across a new University of South Florida lab and education center on the Tampa main campus — impaling-clip mounted treatment cutting RT60 by 0.8 to 1.0 seconds toward ANSI S12.60 academic-space compliance.
Custom 4-inch wood-framed acoustic panels installed inside three new Georgia Public Broadcasting studios in midtown Atlanta — hitting NRC 1.0 down to 250 Hz with bracket and impaling-clip mounting plus calibrated-mic RT60 verification before sign-off.
45 wall-mounted acoustic panels installed across the Pinellas Park Public Works auditorium in Florida — a multi-use municipal meeting space taken from a 2.5-second baseline RT60 down 55% to a workable training and public-comment range.
50 wall-mounted acoustic panels installed in one day inside Westcoast Church’s main sanctuary in Englewood, FL — pulling RT60 from 1.6 seconds down to 1.05 to land squarely inside the worship range for live band and amplified speakers.
Pre-construction acoustic consulting for a four-star Miami hotel amenity lounge under NDA — Sabin-formula reverberation modeling and LEED v4 RT60 targeting against a 1.8-second A-weighted baseline submitted with the developer’s progress drawings.
ASTM E336 field STC leak check and dBA flanking sweep on a shotgun-style duplex demising wall in New Orleans — documenting an ASTC of 35.6 (well below code) and engineering a retrofit recommendation to lift the wall to STC 45+ for multi-family use.
24-hour Class 1 SPL logging plus staff interviews inside Ochsner Medical Center’s 7th-floor neuroscience ICU in New Orleans — building a pre-move HCAHPS-aligned mitigation plan around the noise events most often waking patients overnight.
Ceiling-mounted absorption panels installed across New Orleans Police Department interview rooms — RT60 dropped from 0.9 down to 0.5 seconds well inside the speech-clarity range for the architect Concordia’s NOPD interrogation buildout package.
Wall Blokker Pro membrane overlay plus 5/8″ drywall applied to existing demising walls during the Lakeshore Apartments adaptive reuse — lifting STC from 45 to 50 to meet IBC 1207.1 without burning livable square footage on resilient channels.
32 custom 4’×10′ wood-framed acoustic panels plus ceiling baffles and clouds built for St. Paul’s School’s renovated performance theater in Clearwater — Guilford of Maine fabric wrap and NRC tuned to the architect’s spec over a four-week run.
Lencore sound masking installed across Tru Simulation + Training’s accounting and sales open-office floors in Lutz, FL — a Textron defense subsidiary tuned the system to 47-48 dBA with two-zone control and full room-by-room speaker calibration.