After-hours ASTM E336 field STC testing across key partitions inside Ochsner Medical Center in New Orleans — verifying AHCA compliance and protecting patient-privacy targets at the close-out of the hospital’s recent major expansion phase.
Consulting
Pre-opening noise ordinance compliance testing for an indoor-outdoor Bywater music venue in New Orleans — Type 2 sound-level meter readings, L10 and Lmax baseline data, and a 10-minute capture plan prepped for City Council review under Chapter 66.
Pre-construction acoustic consulting for a four-star Miami hotel amenity lounge under NDA — Sabin-formula reverberation modeling and LEED v4 RT60 targeting against a 1.8-second A-weighted baseline submitted with the developer’s progress drawings.
ASTM E336 field STC leak check and dBA flanking sweep on a shotgun-style duplex demising wall in New Orleans — documenting an ASTC of 35.6 (well below code) and engineering a retrofit recommendation to lift the wall to STC 45+ for multi-family use.
ASTM E336 ASTC field testing across 10 partitions inside Amgen Pharmaceuticals’ Washington, DC corporate office — measuring values from ASTC 27 to 38 across a Teknion modular wall system and pinpointing the flanking paths driving real-world speech transfer.
ASTC field testing plus a modular-wall vs drywall decision-tree framework developed for an Amgen Tampa corporate office — comparing Teknion partitions, Armstrong Calla tiles, and Lencore masking against full drywall to lock in office speech-privacy targets.
Pre-renovation reverberation baseline taken across the Moffitt Cancer Center atrium ahead of replacing the wood flooring with terrazzo — Type 1 SPL meter plus three impulse sources captured RT60 at 10 frequencies to predict the renovation’s acoustic impact.
ISO 10137 footfall vibration assessment for the Providence One commercial office building in Lake Mary, FL — measuring Class 3 perceptible (one magnitude under the action limit) across a 3″ slab on 3-1/4″ corrugated deck supported by W21x44 beams.
ASTM E336 ASTC field testing across an upscale Tampa hotel three years post-opening — diagnosing window-traffic noise, door undercuts, and bar-speaker flanking that left guestrooms at ASTC 47, well above code but short of the luxury 55-60 target.
Hospital-wide HCAHPS sound study across a multi-floor Central Florida acute-care facility — Class 1 SPL meter logging time- and space-stamped noise events, producing a multimodal behavioral plus architectural noise-reduction program for hospital leadership.
Multifamily field defect investigation for an Upstate New York property — pink-noise ASTM E336 ASTC plus ASTM E1007 AIIC tapping-machine testing from 100 Hz to 4000 Hz, pinpointing the stairway and floor-system defects driving resident noise complaints.