IIC 56–58Art District Flats — Denver, CO
63,000 SF of Floor Blokker underlayment met strict IIC targets without heavy rubber mats, reaching IIC 56–58 on 5.5″ slabs while streamlining installation for the GC.
Read the case study →Build your floor-ceiling assembly layer by layer and watch the estimated IIC rating update instantly — then get the lab-tested number for your exact floor.
Impact Insulation Class (IIC) is a standardized single-number rating that quantifies how well a floor-ceiling system attenuates structure-borne impact noise — footsteps, dropped objects, or rolling carts. It is calculated from frequency data collected under ASTM E492, then rated using ASTM E989. Higher IIC values mean better impact isolation and quieter spaces for occupants below.
Floor assemblies vary widely in performance. Carpet over slab delivers high IIC values, while vinyl or tile over a bare slab performs poorly. For hard-surface floors, an acoustic underlayment and a suspended ceiling below boost performance dramatically — especially in wood-framed buildings where vibration travels further.
Small changes in underlayment thickness or ceiling design make big differences. A 10mm underlayment under hardwood on a resiliently-mounted ceiling reaches IIC 57–60, compared to the low 30s with no underlayment and an exposed ceiling. See how IIC, STC, and Delta IIC relate.
| Wood Joist | Concrete | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Ceiling | Underlayment | LVT | Carpet | Tile | Laminate | Hardwood | LVT | Carpet | Tile | Laminate | Hardwood |
| Exposed Ceiling | None | 33 | 47 | 30 | 32 | 32 | 36 | 50 | 33 | 35 | 35 |
| 2mm | 37 | 51 | 34 | 36 | 36 | 40 | 54 | 37 | 39 | 39 | |
| 3mm | 38 | 52 | 35 | 37 | 37 | 41 | 55 | 38 | 40 | 40 | |
| 5mm | 45 | 59 | 42 | 44 | 44 | 48 | 62 | 45 | 47 | 47 | |
| 10mm | 48 | 62 | 45 | 47 | 47 | 51 | 65 | 48 | 50 | 50 | |
| Hard-Mounted Drywall | None | 35 | 49 | 32 | 34 | 34 | 38 | 52 | 35 | 37 | 37 |
| 2mm | 39 | 53 | 36 | 38 | 38 | 42 | 56 | 39 | 41 | 41 | |
| 3mm | 40 | 54 | 37 | 39 | 39 | 43 | 57 | 40 | 42 | 42 | |
| 5mm | 47 | 61 | 44 | 46 | 46 | 50 | 64 | 47 | 49 | 49 | |
| 10mm | 50 | 64 | 47 | 49 | 49 | 53 | 67 | 50 | 52 | 52 | |
| Resiliently-Mounted Drywall | None | 43 | 57 | 40 | 42 | 42 | 46 | 60 | 43 | 45 | 45 |
| 2mm | 47 | 61 | 44 | 46 | 46 | 50 | 64 | 47 | 49 | 49 | |
| 3mm | 48 | 62 | 45 | 47 | 47 | 51 | 65 | 48 | 50 | 50 | |
| 5mm | 55 | 69 | 52 | 54 | 54 | 58 | 72 | 55 | 57 | 57 | |
| 10mm | 58 | 72 | 55 | 57 | 57 | 61 | 75 | 58 | 60 | 60 | |
The International Building Code requires a minimum lab-tested IIC of 50 (or 45 field-tested) between dwelling units in multifamily buildings. Many design teams aim higher — especially in high-end developments, hospitality, and healthcare — and some brands set their own internal standards.
Code Minimum
Education
Hospitality
Healthcare
CommercialA bare slab blocks airborne sound well but does little for impact noise. An 8″ solid slab can rate below IIC 35 without an acoustic mat or suspended ceiling, and ribbed or hollow-core slabs often perform worse — so resilient detailing matters most when hard flooring goes over concrete.
IIC testing uses a standard tapping machine that delivers consistent impacts to the test floor. Microphones in the room below capture the noise across a standardized frequency range, and the results are compared to a reference contour to set the final score.
Improving IIC starts with interrupting vibration transfer — adding mass, decoupling layers, or inserting absorptive materials.
Floor underlayment projects across multifamily, mixed-use, education, and custom homes — with the field-tested numbers to back them up.
IIC 56–5863,000 SF of Floor Blokker underlayment met strict IIC targets without heavy rubber mats, reaching IIC 56–58 on 5.5″ slabs while streamlining installation for the GC.
Read the case study →
IIC 60The former McDonogh 19 Elementary became a Civil Rights museum and senior apartments. 18,000 SF of AcoustiStep under new LVT reached IIC 60 while preserving the building’s historic character.
Read the case study →
AIIC 5275,000 SF of Floor Blokker under hickory hardwood on open-web truss floors — the worst-case assembly — field-tested at ASTC 58 / AIIC 52, beating code by 13 ASTC points.
Read the case study →
RetrofitFood-hall and kitchen noise was bleeding into the second-floor event space. A Floor Blokker retrofit under new hardwood cut airborne and impact noise without ground-up reconstruction.
Read the case study →
Floating LVTA new multi-family build ran Floor Blokker under floating LVT — the highest-performing install method, lab-validated over both wood-frame and concrete subfloors.
Read the case study →
IIC 30s → 45Floor Blokker in the second-story subfloor, installed during framing, lifted IIC from the low 30s to about 45 over the master suite below.
Read the case study →For multifamily buildings, an IIC of 50 (lab) or 45 (field) is required by code. For high-performance or luxury applications, aim for 55–65.
Our calculator estimates based on typical floor assemblies and material combinations. It’s excellent for early design phases or value engineering. For final specs, use lab-tested assemblies or consult an acoustic engineer.
Yes. Acoustic underlayments — like rubber, MLV, cork, or fiber-based mats — can improve IIC by 10–20 points depending on materials used.
Field tests (ASTM E1007) measure real-world performance. Expect results to be 5–10 points lower than lab (ASTM E492) due to installation variables and flanking paths.
No. STC measures airborne sound (like speech); IIC measures impact sound (like footfall). You need both for complete acoustic performance in multi-story buildings.